Incorrect context for function call

Hi,
I get the message 'incorrect context for funtion call' in the
DXL interaction - window, when I click on any object in any module
in the same folder.
Sometimes a URL (of the object?) appears in the DXL interaction INPUT-window!

Restart does not help, using another PC gives the same behaviour.
In other folders - I did not really test them all - the behaviour is OK.
It's also independent of the user, who opens the module - admitted, I tested
only one other user

How to turn this behaviour off?

Best regrds,
Dolf
DolfRiedel - Fri Apr 01 02:27:44 EDT 2011

Re: Incorrect context for function call
Mathias Mamsch - Fri Apr 01 05:07:28 EDT 2011

That looks like a project bound sync trigger goes rogue on you ... Try using the "Delete Persistent Triggers" script from Galactic Solutions to determine if there are any triggers installed on your folder or database.

I know that there are other nice scripts on the forum from Louie which will help you to determine the triggers that apply to a module.

If you have the possibility to launch as Administrator, try launching DOORS with the -notrigger option and see if the behaviour persists.

Regards, Mathais

Mathias Mamsch, IT-QBase GmbH, Consultant for Requirement Engineering and D00RS

Re: Incorrect context for function call
DolfRiedel - Tue May 17 02:06:16 EDT 2011

Thanks Matthias - that worked.

Re: Incorrect context for function call
DolfRiedel - Tue May 17 02:07:21 EDT 2011

Thanks MAtthias, that worked